Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 159
Filter
1.
J Anal Toxicol ; 44(7): 708-717, 2020 Oct 12.
Article in English | MEDLINE | ID: mdl-32808043

ABSTRACT

An analytical method for the detection of 40 benzodiazepines, (±)-zopiclone, zaleplon and zolpidem in blood and urine by solid-phase extraction liquid chromatography-tandem mass spectrometry was developed and validated. Twenty-nine of 43 analytes were quantified in 0.5 mL whole blood for investigating postmortem, drug-facilitated sexual assault (DFSA) and driving under the influence of drugs cases (DUID). The four different dynamic ranges of the seven-point, linear, 1/x weighted calibration curves with lower limits of quantification of 2, 5, 10 and 20 µg/L across the analytes encompassed the majority of our casework encountered in postmortem, DFSA and DUID samples. Reference materials were available for all analytes except α-hydroxyflualprazolam, a hydroxylated metabolite of flualprazolam. The fragmentation of α-hydroxyflualprazolam was predicted from the fragmentation pattern of α-hydroxyalprazolam, and the appropriate transitions were added to the method to enable monitoring for this analyte. Urine samples were hydrolyzed at 55°C for 30 min with a genetically modified ß-glucuronidase enzyme, which resulted in >95% efficiency measured by oxazepam glucuronide. Extensive sample preparation included combining osmotic lysing and protein precipitation with methanol/acetonitrile mixture followed by freezing and centrifugation resulted in exceptionally high signal-to-noise ratios. Bias and between-and within-day imprecision for quality controls (QCs) were all within ±15%, except for clonazolam and etizolam that were within ±20%. All 29 of the 43 analytes tested for QC performance met quantitative reporting criteria within the dynamic ranges of the calibration curves, and 14 analytes, present only in the calibrator solution, were qualitatively reported. Twenty-five analytes met all quantitative reporting criteria including dilution integrity. The ability to analyze quantitative blood and qualitative urine samples in the same batch is one of the most useful elements of this procedure. This sensitive, specific and robust analytical method was routinely employed in the analysis of >300 samples in our laboratory over the last 6 months.


Subject(s)
Benzodiazepines/metabolism , Hypnotics and Sedatives/metabolism , Substance Abuse Detection/methods , Alprazolam/analogs & derivatives , Azabicyclo Compounds/blood , Azabicyclo Compounds/metabolism , Azabicyclo Compounds/urine , Benzodiazepines/blood , Benzodiazepines/urine , Chromatography, Liquid/methods , Diazepam/analogs & derivatives , Forensic Toxicology , Humans , Hypnotics and Sedatives/analysis , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Limit of Detection , Piperazines/blood , Piperazines/metabolism , Piperazines/urine , Sleep Aids, Pharmaceutical/blood , Sleep Aids, Pharmaceutical/metabolism , Sleep Aids, Pharmaceutical/urine , Solid Phase Extraction/methods , Tandem Mass Spectrometry/methods , Zolpidem/blood , Zolpidem/metabolism , Zolpidem/urine
2.
Clin Pharmacol Ther ; 108(5): 1003-1009, 2020 11.
Article in English | MEDLINE | ID: mdl-32386327

ABSTRACT

Growth and development affect drug-metabolizing enzyme activity thus could alter the metabolic profile of a drug. Traditional studies to create metabolite profiles and study the routes of excretion are unethical in children due to the high radioactive burden. To overcome this challenge, we aimed to show the feasibility of an absorption, distribution, metabolism, and excretion (ADME) study using a [14 C]midazolam microtracer as proof of concept in children. Twelve stable, critically ill children received an oral [14 C]midazolam microtracer (20 ng/kg; 60 Bq/kg) while receiving intravenous therapeutic midazolam. Blood was sampled up to 24 hours after dosing. A time-averaged plasma pool per patient was prepared reflecting the mean area under the curve plasma level, and subsequently one pool for each age group (0-1 month, 1-6 months, 0.5-2 years, and 2-6 years). For each pool [14 C]levels were quantified by accelerator mass spectrometry, and metabolites identified by high resolution mass spectrometry. Urine and feces (n = 4) were collected up to 72 hours. The approach resulted in sufficient sensitivity to quantify individual metabolites in chromatograms. [14 C]1-OH-midazolam-glucuronide was most abundant in all but one age group, followed by unchanged [14 C]midazolam and [14 C]1-OH-midazolam. The small proportion of unspecified metabolites most probably includes [14 C]midazolam-glucuronide and [14 C]4-OH-midazolam. Excretion was mainly in urine; the total recovery in urine and feces was 77-94%. This first pediatric pilot study makes clear that using a [14 C]midazolam microtracer is feasible and safe to generate metabolite profiles and study recovery in children. This approach is promising for first-in-child studies to delineate age-related variation in drug metabolite profiles.


Subject(s)
Carbon Radioisotopes/pharmacokinetics , Hypnotics and Sedatives/pharmacokinetics , Midazolam/pharmacokinetics , Administration, Intravenous , Administration, Oral , Age Factors , Biotransformation , Carbon Radioisotopes/administration & dosage , Carbon Radioisotopes/blood , Carbon Radioisotopes/urine , Child , Child, Preschool , Critical Illness , Feasibility Studies , Feces/chemistry , Female , Humans , Hypnotics and Sedatives/administration & dosage , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Infant , Infant, Newborn , Intensive Care Units, Pediatric , Intestinal Elimination , Male , Mass Spectrometry , Midazolam/administration & dosage , Midazolam/blood , Midazolam/urine , Proof of Concept Study , Renal Elimination
3.
J Anal Toxicol ; 42(7): 491-495, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-29750249

ABSTRACT

Zolpidem (Ambien®) is one of the "Z" drugs often used to improve sleep in older patients and those suffering from insomnia. Schwope, D.M., DePriest, A., Black, D.L., Caplan, Y.H., Cone, E.J., Heltsley, R. (2014) Determing zolpidem compliance: urinary metabolite detection and prevalence in chronic pain patients . Journal of Analytical Toxicology, 38, 513-518 reported that zolpidem in urine is not very prevalent being present <23% of the time in patient urine while the major metabolite, zolpidem 4-phenyl carboxylic acid (ZCA), is much more prevalent in urine with positive rates as high as 50% of the patient samples reviewed. Results from patient testing over a year's time are in agreement with the reported zolpidem results. However, the data observed herein for ZCA are not consistent with the earlier report. These data suggest that monitoring ZCA may result in even higher levels of positivity. Further, while the Food and Drug Administration has pointed out that female dosing should be half that given to males, results of this population testing indicate that the majority of patients (83% male and 73% female) receive 10 mg/day or 12.5 mg/day for Ambien CR® with females demonstrating statistically significantly higher levels of ZCA albeit zolpidem levels are not statistically significantly different between men and women. Estimates of patient positivity are dependent upon the value of the limit of quantification (LOQ) as demonstrated by the zolpidem results herein (LOQ = 50 ng/mL vs. 4 ng/mL). However, even with a much higher LOQ of 50 ng/mL for ZCA in this work, the positivity from ZCA results is significantly higher (e.g., 64.8%) than reported earlier (50.3%). Nevertheless, these data support the addition of ZCA for monitoring zolpidem in urine.


Subject(s)
Drug Monitoring/methods , Hypnotics and Sedatives/urine , Pyridines/urine , Zolpidem/urine , Administration, Oral , Biotransformation , Chromatography, Liquid , Drug Dosage Calculations , Female , Humans , Hypnotics and Sedatives/administration & dosage , Male , Reproducibility of Results , Sex Factors , Tablets , Tandem Mass Spectrometry , Urinalysis , Zolpidem/administration & dosage
4.
J Anal Toxicol ; 41(9): 771-776, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28977429

ABSTRACT

Two cases of suspected acute and lethal intoxication caused by propofol were delivered by the judicial authority to the Department of Sciences for Health Promotion and Mother-Child Care in Palermo, Sicily. In the first case a female nurse was found in a hotel room, where she lived with her mother; four 10 mg/mL vials and two 20 mg/mL vials of propofol were found near the decedent along with syringes and needles. In the second case a male nurse was found in the operating room of a hospital, along with a used syringe. In both cases a preliminary systematic and toxicological analysis indicated the presence of propofol in the blood and urine. As a result, a method for the quantitative determination of propofol in biological fluids was optimized and validated using a liquid-liquid extraction protocol followed by GC/MS and fast GC/MS-TOF. In the first case, the concentration of propofol in blood was determined to be 8.1 µg/mL while the concentration of propofol in the second case was calculated at 1.2 µg/mL. Additionally, the tissue distribution of propofol was determined for both cases. Brain and liver concentrations of propofol were, respectively, 31.1 and 52.2 µg/g in Case 1 and 4.7 and 49.1 µg/g in Case 2. Data emerging from the autopsy findings, histopathological exams as well as the toxicological results aided in establishing that the deaths were due to poisoning, however, the manner of death in each were different: homicide in Case 1 and suicide in Case 2.


Subject(s)
Drug Overdose/diagnosis , Hypnotics and Sedatives/metabolism , Propofol/metabolism , Drug Overdose/blood , Drug Overdose/urine , Female , Forensic Toxicology , Gas Chromatography-Mass Spectrometry , Homicide , Humans , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Male , Propofol/blood , Propofol/urine , Suicide
5.
Am J Drug Alcohol Abuse ; 43(6): 686-693, 2017 11.
Article in English | MEDLINE | ID: mdl-28662343

ABSTRACT

BACKGROUND: γ-hydroxybutyrate (GHB) has a high potential for illicit use; overdose of this compound results in sedation, respiratory depression and death. Tolerance to the hypnotic/sedative and electroencephalogram effects of GHB occurs with chronic GHB administration; however, tolerance to respiratory depression has not been evaluated. GHB toxicodynamic effects are mediated predominantly by GABAB receptors. Chronic treatment may affect monocarboxylate transporters (MCTs) and alter the absorption, renal clearance and brain uptake of GHB. OBJECTIVES: To determine effects of chronic GHB dosing on GHB toxicokinetics, GHB-induced respiratory depression, and MCT expression. METHODS: Rats were administered GHB 600 mg/kg intravenously daily for 5 days. Plasma, urine and tissue samples and respiratory measurements were obtained on days 1 and 5. Plasma and urine were analyzed for GHB by LC/MS/MS and tissue samples for expression of MCT1, 2 and 4 and their accessory proteins by QRT-PCR. RESULTS: No differences in GHB pharmacokinetics or respiratory depression were observed between days 1 and 5. Opposing changes in MCT1 and MCT4 mRNA expression were observed in kidney samples on day 5 compared to GHB-naïve animals, and MCT4 expression was increased in the intestine. CONCLUSIONS: The lack of tolerance observed with GHB-induced respiratory depression, in contrast to the tolerance reported for the sedative/hypnotic and electroencephalogram effects, suggests that different GABAB receptor subtypes may be involved in different GABAB-mediated toxicodynamic effects of GHB. Chronic or binge users of GHB may be at no less risk for fatality from respiratory arrest with a GHB overdose than with a single dose of GHB.


Subject(s)
Monocarboxylic Acid Transporters/biosynthesis , Respiratory Insufficiency/chemically induced , Sodium Oxybate/adverse effects , Sodium Oxybate/pharmacokinetics , Animals , Cells, Cultured , Hypnotics and Sedatives/adverse effects , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/pharmacokinetics , Hypnotics and Sedatives/urine , Male , Rats , Sodium Oxybate/blood , Sodium Oxybate/urine , Time Factors , Toxicokinetics
6.
J Pharm Biomed Anal ; 137: 78-83, 2017 Apr 15.
Article in English | MEDLINE | ID: mdl-28104560

ABSTRACT

Remimazolam is a new chemical entity belonging to the benzodiazepine class of sedative drugs, which shows faster-acting onset and recovery than currently available short-acting sedatives. In the present study, ultra high performance liquid chromatography with synapt high-definition mass spectrometry method combined with MassLynx software was established to characterize metabolites of remimazolam in human plasma and urine. In total, 5 human metabolites were detected, including 3 phase I and 2 phase II metabolites. There was no novel human metabolite detected compared to that in rat. Hydrolysis, glucuronidation and oxidation were the major metabolic reactions. To our knowledge, this is the first report of the human metabolic profile of remimazolam.


Subject(s)
Benzodiazepines/blood , Benzodiazepines/urine , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Animals , Chromatography, High Pressure Liquid/methods , Double-Blind Method , Humans , Rats , Software , Tandem Mass Spectrometry/methods
7.
J Anal Toxicol ; 41(1): 1-5, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28130542

ABSTRACT

High-resolution mass spectrometry (HRMS) has gained recognition as a valuable tool for comprehensive drug screening in a variety of biological matrices. HRMS instruments collect untargeted, accurate mass data, which permit identification of known and unknown compounds in a single analytical run. One of the most challenging aspects of implementing an HRMS drug screen is establishing appropriate data analysis parameters for identifying compounds. Unlike other types of mass spectrometry data, guidelines for HRMS data analysis and acceptability criteria have not been established. Although many laboratories have published on the utility of HRMS for drug screening, few have included details on how they determined allowable errors and set positivity criteria. Previously, we developed and validated a comprehensive 169-compound drug screen on a high-resolution quadrupole time of flight mass spectrometer. Here we report the detailed procedure that we used to determine appropriate positivity criteria for our screening procedure. Our approach was empirical; we collected data and analyzed it with commonly available software. We found that a combined scoring approach using a threshold of 70, with 70% weight given to library match and 10% weight given to each of mass error, retention time error and isotope pattern difference provided optimum drug identification efficiency of 99.2%. Our results demonstrate the importance of library matching in accurately identifying compounds, and underscore the utility of robust product ion spectra that contain information on the lineage, mass and relative abundance of fragments. The method we describe is easily adaptable to include alternative parameters that may be available in software associated with a variety of HRMS platforms. With careful selection of error limits and positivity criteria, HRMS instruments are capable of producing high-quality, high-confidence results that may reduce the need for confirmatory testing.


Subject(s)
Drug Monitoring/methods , Substance Abuse Detection/methods , Tandem Mass Spectrometry/methods , Analgesics, Opioid/urine , Antidepressive Agents/urine , Antipsychotic Agents/urine , Central Nervous System Stimulants/urine , Chromatography, Liquid , Humans , Hypnotics and Sedatives/urine , Reproducibility of Results , Sensitivity and Specificity , Software
8.
Fa Yi Xue Za Zhi ; 33(6): 635-639, 2017 Dec.
Article in Chinese | MEDLINE | ID: mdl-29441774

ABSTRACT

As a new hypnotic, zopiclone is widely used in clinical treatment. There are many methods for determination of zopiclone, including spectrophotometry, chromatography and chromatography mass spectrum, etc. Present paper reviews different kinds of biological samples associated with zopiclone, extraction and purification methods, and determination and analysis methods, which aims to provide references for the relevant research and practice.


Subject(s)
Azabicyclo Compounds/blood , Azabicyclo Compounds/urine , Chromatography, High Pressure Liquid/methods , Gas Chromatography-Mass Spectrometry , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Piperazines/blood , Piperazines/urine , Tandem Mass Spectrometry/methods , Azabicyclo Compounds/metabolism , Humans , Hypnotics and Sedatives/metabolism , Mass Spectrometry , Piperazines/metabolism
9.
J Anal Toxicol ; 40(8): 663-668, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27550995

ABSTRACT

Forensic laboratories are challenged with backlogs that produce turnaround times that vary from days to months. Therefore, drug stability is important for interpretation in both antemortem (blood and urine) and postmortem (blood, brain, liver, stomach contents) cases. In this study, 23 benzodiazepines (2-hydroxyethylflurazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, α-hydroxyalprazolam, α-hydroxytriazolam, alprazolam, bromazepam, chlordiazepoxide, clonazepam, demoxepam, desalkylflurazepam, diazepam, estazolam, flunitrazepam, flurazepam, lorazepam, midazolam, nitrazepam, nordiazepam, oxazepam, phenazepam, temazepam and triazolam) and three sedative hypnotics (zaleplon, zopiclone and zolpidem) were spiked into the six matrices at two different concentrations for each drug. The samples were stored in either a refrigerator (4°C) or freezer (-20°C) and analyzed in triplicate at various time intervals over an 8-month period using an SWGTOX validated method. The concentrations decreased over time regardless of the initial spiked concentration, and the storage conditions had little effect on the decrease of most drugs. Conversion from drug to metabolite was difficult to determine since all 26 drugs were present in each sample. Zopiclone and phenazepam were the least stable drugs; zopiclone was the only drug that completely disappeared in any matrix (both antemortem and postmortem blood). Urine was the most stable matrix with only phenazepam, 7-aminoclonazepam, 7-aminoflunitrazepam, 2-hydroxyethylflurazepam, and zopiclone decreasing >20% over the 8 months in either storage condition. Postmortem blood, the least stable matrix, had only two drugs, zolpidem and bromazepam, decreasing <20% in the 8-month time period. Further experiments on stability of these drugs should be undertaken to remove the freeze-thaw cycle effect and more thoroughly examining drug-metabolite conversion.


Subject(s)
Benzodiazepines/blood , Benzodiazepines/urine , Drug Stability , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Specimen Handling/methods , Benzodiazepines/chemistry , Brain/drug effects , Brain/metabolism , Calibration , Cold Temperature , Diagnosis , Freezing , Humans , Hydrogen-Ion Concentration , Hypnotics and Sedatives/chemistry , Limit of Detection , Liver/drug effects , Liver/metabolism , Refrigeration , Reproducibility of Results , Tandem Mass Spectrometry
10.
Article in English | MEDLINE | ID: mdl-27236533

ABSTRACT

We present a UPLC(®)-High Resolution Mass Spectrometric method to simultaneously screen for nineteen benzodiazepines, twelve opiates, cocaine and three metabolites, and three "Z-drug" hypnotic sedatives in both blood and urine specimens. Sample processing consists of a high-speed, high-temperature enzymatic hydrolysis for urine samples followed by a rapid supported liquid extraction (SLE). The combination of ultra-high resolution chromatography with high resolution mass spectrometry allows all 38 analytes to be uniquely detected with a ten minute analytical run. Limits of detection for all target analytes are 3ng/mL or better, with only 0.3mL of specimen used for analysis. The combination of low sample volume with fast processing and analysis makes this method a suitable replacement for immunoassay screening of the targeted drug classes, while providing far superior specificity and better limits of detection than can routinely be obtained by immunoassay.


Subject(s)
Chromatography, High Pressure Liquid/methods , Spectrometry, Mass, Electrospray Ionization/methods , Substance Abuse Detection/methods , Benzodiazepines/blood , Benzodiazepines/urine , Chromatography, High Pressure Liquid/economics , Chromatography, High Pressure Liquid/instrumentation , Cocaine/blood , Cocaine/urine , Equipment Design , Humans , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Limit of Detection , Opiate Alkaloids/blood , Opiate Alkaloids/urine , Spectrometry, Mass, Electrospray Ionization/economics , Spectrometry, Mass, Electrospray Ionization/instrumentation , Substance Abuse Detection/economics , Substance Abuse Detection/instrumentation , Time Factors
11.
Article in English | MEDLINE | ID: mdl-27107852

ABSTRACT

Date-rape drugs have the potential to be used in drug-facilitated sexual assault, organ theft and property theft. Since they are colorless, tasteless and odorless, victims can drink without noticing, when added to the beverages. These drugs must be detected in time, before they are cleared up from the biofluids. A simultaneous extraction and determination method in urine for GHB, ketamine, norketamine, phenobarbital, thiopental, zolpidem, zopiclone and phenytoin (an anticonvulsant and antiepileptic drug) with LC-MS/MS was developed for the first time with analytically acceptable recoveries and validated. A 4 steps liquid-liquid extraction was applied, using only 1.000mL urine. A new age commercial C18 poroshell column with high column efficiency was used for LC-MS/MS analysis with a fast isocratic elution as 5.5min. A new MS transition were introduced for barbital. 222.7>179.8 with the effect of acetonitrile. Recoveries (%) were between 80.98-99.27 for all analytes, except for GHB which was 71.46. LOD and LOQ values were found in the ranges of 0.59-49.50 and 9.20-80.80ngmL(-1) for all the analytes (except for GHB:3.44 and 6.00µgmL(-1)). HorRat values calculated (between 0.25-1.21), revealed that the inter-day and interanalist precisions (RSD%≤14.54%) acceptable. The simultaneous extraction and determination of these 8 analytes in urine is challenging because of the difficulty arising from the different chemical properties of some. Since the procedure can extract drugs from a wide range of polarity and pKa, it increases the window of detection. Group representatives from barbiturates, z-drugs, ketamine, phenytoin and polar acidic drugs (GHB) have been successfully analyzed in this study with low detection limits. The method is important from the point of determining the combined or single use of these drugs in crimes and finding out the reasons of deaths related to these drugs.


Subject(s)
Chromatography, High Pressure Liquid/methods , Hypnotics and Sedatives/urine , Liquid-Liquid Extraction/methods , Azabicyclo Compounds/chemistry , Azabicyclo Compounds/isolation & purification , Azabicyclo Compounds/urine , Barbiturates/chemistry , Barbiturates/isolation & purification , Barbiturates/urine , Forensic Sciences , Humans , Hypnotics and Sedatives/chemistry , Hypnotics and Sedatives/isolation & purification , Ketamine/chemistry , Ketamine/isolation & purification , Ketamine/urine , Limit of Detection , Linear Models , Phenytoin/chemistry , Phenytoin/isolation & purification , Phenytoin/urine , Piperazines/chemistry , Piperazines/isolation & purification , Piperazines/urine , Pyridines/chemistry , Pyridines/isolation & purification , Pyridines/urine , Rape , Reproducibility of Results , Sodium Oxybate/chemistry , Sodium Oxybate/isolation & purification , Sodium Oxybate/urine , Zolpidem
12.
Biochem Pharmacol ; 109: 70-82, 2016 06 01.
Article in English | MEDLINE | ID: mdl-27021842

ABSTRACT

Agomelatine (AGM), an analog of melatonin, is a potential agonist at melatonin receptors 1/2 and a selective antagonist at 5-hydroxytryptamine 2C receptors. AGM is widely used for the treatment of major depressive episodes in adults. However, multiple adverse effects associated with AGM have been reported in clinical practice. It is little known about AGM metabolism in vitro and in vivo, although metabolism plays a pivotal role in its efficacy and safety. To elucidate metabolic pathways of AGM, we systemically investigated AGM metabolism and its bioactivation in human liver microsomes (HLM) and mice using metabolomic approaches. We identified thirty-eight AGM metabolites and adducts, among which thirty-two are novel. In HLM, we uncovered five GSH-trapped adducts and two semicarbazide-trapped aldehydes. Moreover, we characterized three N-acetyl cysteine conjugated-AGM adducts in mouse urine and feces, which were formed from the degradation of AGM_GSH adducts. Using recombinant CYP450 isoenzymes and chemical inhibitors, we demonstrated that CYP1A2 and CYP3A4 are primary enzymes contributing to the formation of AGM_GSH adducts and AGM_hydrazones. This study provided a global view of AGM metabolism and identified the novel pathways of AGM bioactivation, which could be utilized for further understanding the mechanism of adverse effects related to AGM and possible drug-drug interactions.


Subject(s)
Acetamides/urine , Cytochrome P-450 Enzyme System/metabolism , Hypnotics and Sedatives/urine , Microsomes, Liver/metabolism , Receptors, Melatonin/agonists , Acetamides/chemistry , Acetamides/pharmacokinetics , Animals , Biotransformation , Feces/chemistry , Gene Expression Regulation , Glutathione/chemistry , Humans , Hypnotics and Sedatives/chemistry , Hypnotics and Sedatives/pharmacokinetics , Isoenzymes/metabolism , Metabolic Networks and Pathways/genetics , Metabolomics , Mice , Mice, Inbred ICR , Microsomes, Liver/drug effects , Receptors, Melatonin/genetics , Receptors, Melatonin/metabolism , Semicarbazides/chemistry , Signal Transduction
13.
Forensic Sci Int ; 257: 84-92, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26282513

ABSTRACT

Benzodiazepines and zolpidem are generally prescribed as sedative, hypnotics, anxiolytics or anticonvulsants. These drugs, however, are frequently misused in drug-facilitated crime. Therefore, a rapid and simple liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of benzodiazepines, zolpidem and their metabolites in urine using deuterium labeled internal standards (IS). Urine samples (120 µL) mixed with 80 µL of the IS solution were centrifuged. An aliquot (5 µL) of the sample solution was directly injected into the LC-MS/MS system for analysis. The mobile phases consisted of water and acetonitrile containing 2mM ammonium trifluoroacetate and 0.2% acetic acid. The analytical column was a Zorbax SB-C18 (100 mm × 2.1 mm i.d., 3.5 µm, Agilent). The separation and detection of 18 analytes were achieved within 10 min. Calibration curves were linear over the concentration ranges of 0.5-20 ng/mL (zolpidem), 1.0-40 ng/mL (flurazepam and temazepam), 2.5-100 ng/mL (7-aminoclonazepam, 1-hydroxymidazolam, midazolam, flunitrazepam and alprazolam), 5.0-200 ng/mL (zolpidem phenyl-4-carboxylic acid, α-hydroxyalprazolam, oxazepam, nordiazepam, triazolam, diazepam and α-hydroxytriazolam), 10-400 ng/mL (lorazepam and desalkylflurazepam) and 10-100 ng/mL (N-desmethylflunitrazepam) with the coefficients of determination (r(2)) above 0.9971. The dilution integrity of the analytes was examined for supplementation of short linear range. Dilution precision and accuracy were tested using two, four and ten-folds dilutions and they ranged from 3.7 to 14.4% and -12.8 to 12.5%, respectively. The process efficiency for this method was 63.0-104.6%. Intra- and inter-day precisions were less than 11.8% and 9.1%, while intra- and inter-day accuracies were less than -10.0 to 8.2%, respectively. The lower limits of quantification were lower than 10 ng/mL for each analyte. The applicability of the developed method was successfully verified with human urine samples from drug users (n=21). Direct urine sample injection and optimized mobile phases were introduced for simple sample preparation and high-sensitivity with the desired separation.


Subject(s)
Benzodiazepines/urine , Chromatography, Liquid/methods , Hypnotics and Sedatives/urine , Pyridines/urine , Tandem Mass Spectrometry/methods , Alprazolam/analogs & derivatives , Alprazolam/urine , Flurazepam/analogs & derivatives , Flurazepam/urine , Forensic Toxicology/methods , Humans , Limit of Detection , Triazolam/analogs & derivatives , Triazolam/urine , Zolpidem
14.
Neuropsychopharmacology ; 40(13): 2969-80, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26038159

ABSTRACT

Humans liberally use ethanol for its facilitating effects on social interactions but its effects on central nervous system function remain underexplored. We have recently described that very low doses of ethanol abolish long-term potentiation (LTP)-like plasticity in human cortex, most likely through enhancement of tonic inhibition [Lücke et al, 2014, Neuropsychopharmacology 39:1508-18]. Here, we studied the effects of low-dose ethanol on long-term depression (LTD)-like plasticity. LTD-like plasticity was induced in human motor cortex by paired associative transcranial magnetic stimulation (PASLTD), and measured as decreases of motor evoked potential input-output curve (IO-curve). In addition, sedation was measured by decreases in saccade peak velocity (SPV). Ethanol in two low doses (EtOH<10mM, EtOH<20mM) was compared to single oral doses of alprazolam (APZ, 1mg) a classical benzodiazepine, and zolpidem (ZLP, 10 mg), a non-benzodiazepine hypnotic, in a double-blinded randomized placebo-controlled crossover design in ten healthy human subjects. EtOH<10mM and EtOH<20mM but not APZ or ZLP enhanced the PASLTD-induced LTD-like plasticity, while APZ and ZLP but not EtOH<10mM or EtOH<20mM decreased SPV. Non-sedating low doses of ethanol, easily reached during social drinking, enhance LTD-like plasticity in human cortex. This effect is most likely explained by the activation of extrasynaptic α4-subunit containing gamma-aminobutyric type A receptors by low-dose EtOH, resulting in increased tonic inhibition. Findings may stimulate cellular research on the role of tonic inhibition in regulating excitability and plasticity of cortical neuronal networks.


Subject(s)
Central Nervous System Depressants/administration & dosage , Ethanol/administration & dosage , Motor Cortex/drug effects , Motor Cortex/physiology , Neuronal Plasticity/drug effects , Neuronal Plasticity/physiology , Administration, Oral , Adult , Alprazolam/administration & dosage , Alprazolam/blood , Alprazolam/urine , Central Nervous System Depressants/blood , Central Nervous System Depressants/urine , Cross-Over Studies , Dose-Response Relationship, Drug , Double-Blind Method , Electromyography , Ethanol/blood , Ethanol/urine , Evoked Potentials, Motor/drug effects , Hand/physiology , Humans , Hypnotics and Sedatives/administration & dosage , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine , Muscle, Skeletal/drug effects , Muscle, Skeletal/physiology , Pyridines/administration & dosage , Pyridines/blood , Pyridines/urine , Transcranial Magnetic Stimulation/methods , Young Adult , Zolpidem
15.
J Pharm Biomed Anal ; 113: 239-64, 2015 Sep 10.
Article in English | MEDLINE | ID: mdl-25779536

ABSTRACT

Benzodiazepine drugs belong to important and most widely used medicaments. They demonstrate such therapeutic properties as anxiolytic, sedative, somnifacient, anticonvulsant, diastolic and muscle relaxant effects. However, despite the fact that benzodiazepines possess high therapeutic index and are considered to be relatively safe, their use can be dangerous when: (1) co-administered with alcohol, (2) co-administered with other medicaments like sedatives, antidepressants, neuroleptics or morphine like substances, (3) driving under their influence, (4) using benzodiazepines non-therapeutically as drugs of abuse or in drug-facilitated crimes. For these reasons benzodiazepines are still studied and determined in a variety of biological materials. In this article, sample preparation techniques which have been applied in analysis of benzodiazepine drugs in biological samples have been reviewed and presented. The next part of the article is focused on a review of analytical methods which have been employed for pharmacological, toxicological or forensic study of this group of drugs in the biological matrices. The review was preceded by a description of the physicochemical properties of the selected benzodiazepines and two, very often coexisting in the same analyzed samples, sedative-hypnotic drugs.


Subject(s)
Benzodiazepines/blood , Benzodiazepines/urine , Chemistry, Pharmaceutical/methods , Animals , Anti-Anxiety Agents/analysis , Anti-Anxiety Agents/blood , Anti-Anxiety Agents/urine , Benzodiazepines/analysis , Biomarkers/analysis , Biomarkers/blood , Biomarkers/urine , Chemistry, Pharmaceutical/trends , Humans , Hypnotics and Sedatives/analysis , Hypnotics and Sedatives/blood , Hypnotics and Sedatives/urine
16.
Forensic Sci Int ; 243: 149-55, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25199615

ABSTRACT

We report on a case of repeated MDPV consumptions that resulted in severe psychosis and agitation prompting the concomitant abuse of benzodiazepines. A 27-year-old man was found irresponsive in his apartment and was brought to the emergency department (ED) of a local hospital. When in ED, he rapidly recovered and self-reported to have recently injected some doses of MDPV that he had bought in the Internet. He left the hospital without medical cares. 15 days after, he was again admitted to the same ED due to severe agitation, delirium and hallucinations, and reported the use of MDPV and pharmaceutical drugs during the preceding week. He was sedated with diazepam and chlorpromazine. Urine samples collected in both occasions were sent for testing using liquid chromatography-high resolution mass spectrometry (LC-HRMS) and liquid chromatography-high resolution multiple mass spectrometry (LC-HRMS/MS) on an Orbitrap. The LC-HRMS analysis revealed the presence of MDPV and its phase I and phase II metabolites (demethylenyl-MDPV, demethylenyl-methyl-MDPV, demethylenyl-methyl-oxo-MDPV, demethylenyl-hydroxy-alkyl-MDPV, demethylenyl-methyl-hydroxy alkyl-MDPV, demethylenyl-oxo-MDPV and their corresponding glucuronides), alprazolam and alprazolam metabolite at the first ED admission; at the time of the second ED access, the same MDPV metabolites, alprazolam, temazepam, and chlordiazepoxide were detected together with diazepam and metabolites. LC-HRMS/MS was use to determine the following concentrations, respectively on his first and second admission: MDPV 55ng/mL, alprazolam 114ng/mL, α-hydroxyalprazolam 104ng/mL; MDPV 35ng/mL, alprazolam 10.4ng/mL, α -hydroxyalprazolam 13ng/mL; chlordiazepoxide 13ng/mL, temazepam 170ng/mL, diazepam 1.3ng/mL, nordiazepam 61.5, oxazepam 115ng/mL. The toxicological findings corroborated the referred concomitant use of multiple pharmaceutical drugs and benzodiazepines. Confirmation of previous hypothesis on human metabolism of MDPV could be inferred by the analysis of urine.


Subject(s)
Benzodiazepines/urine , Benzodioxoles/urine , Psychotropic Drugs/urine , Pyrrolidines/urine , Adult , Alprazolam/analogs & derivatives , Alprazolam/urine , Chlordiazepoxide/urine , Chromatography, Liquid , Diazepam/urine , Humans , Hypnotics and Sedatives/urine , Male , Mass Spectrometry/methods , Nordazepam/urine , Oxazepam/urine , Substance-Related Disorders/urine , Temazepam/urine , Synthetic Cathinone
17.
J Anal Toxicol ; 38(8): 513-8, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25217539

ABSTRACT

Zolpidem (Ambien(®)) is the most prescribed insomnia treatment in the USA; however, little is known about zolpidem metabolite excretion in chronic pain patients. As zolpidem is extensively metabolized in vivo to zolpidem 4-phenyl carboxylic acid (ZCA), metabolite detection may provide improved accuracy for compliance determinations, thereby improving clinical decisions. Zolpidem and ZCA were extracted from 1 mL human urine by mixed-mode solid-phase extraction. Samples were analyzed by LC-MS-MS using positive electrospray ionization with multiple reaction monitoring mode employed for detection and quantification. Gradient chromatographic separation was achieved with a reversed-phase column in a rapid 1.8 min analysis. The assay was linear from 4 to 1,000 µg/L for zolpidem and 4 to 10,000 µg/L for ZCA. Interday recovery (bias) and imprecision (n = 20) were 100-107% of target and 2.4-3.7% relative standard deviation, respectively. Extraction efficiencies were 78-90%. Pain compliance samples (n = 3,142) were de-identified and analyzed for zolpidem and ZCA. Zolpidem was detected greater than limit of quantification in 720 specimens (22.9%), while ZCA was detected in 1,579 specimens (50.3%). Only five specimens contained zolpidem alone. ZCA was observed without parent zolpidem in 864 specimens, thereby increasing population detection rates by 27.5%. Addition of a zolpidem metabolite to compliance determinations substantially improved detection for zolpidem intake and also should prove useful in clinical and forensic settings.


Subject(s)
Chronic Pain/drug therapy , Hypnotics and Sedatives/urine , Pyridines/urine , Chromatography, Liquid/methods , Chronic Pain/urine , Humans , Limit of Detection , Reproducibility of Results , Sensitivity and Specificity , Solid Phase Extraction , Tandem Mass Spectrometry/methods , Zolpidem
18.
J Addict Med ; 8(5): 333-7, 2014.
Article in English | MEDLINE | ID: mdl-25100309

ABSTRACT

BACKGROUND: Benzodiazepines were introduced for clinical use since the 1960s and rapidly became the sedative-hypnotic of choice. The purpose of this study was to determine whether benzodiazepine use as measured by drug tests is higher in postaccident drug tests than in random tests. METHODS: This is a case-control study comparing the proportion of benzodiazepine laboratory positive urine specimens for random versus postaccident samples. Any sample that tested positive for 1 or more substances other than benzodiazepines was eliminated from the study to correct for the confounding effect of other potentially impairing substances. The group prevalence of benzodiazepine positive samples was compared via the odds ratio with 95% confidence intervals and the P-values. RESULTS: The study began with 4756 urine samples with 2161 postaccident specimens and 2595 random specimens. A total of 243 of the samples were confirmed positive for drugs other than benzodiazepines. The study was left with 2016 postaccident and 2497 random samples. In the controlled postaccident group, there were 57 positive screens and 17 (29.8%) were confirmed as positive for either a benzodiazepine or benzodiazepine metabolites. In the controlled random group, there were 48 positive screens and 10 (20.8%) were confirmed as positive for either a benzodiazepine or benzodiazepine metabolites. The OR comparing the total confirmed laboratory positive benzodiazepine specimens after controlling for other substances was 2.1150 (0.9663-4.6292) with a P-value of 0.0609. CONCLUSIONS: The results for comparing the total confirmed laboratory positive benzodiazepine tests controlled for other substances, although suggestive of an association, did not achieve statistical significance.


Subject(s)
Accidents, Occupational/statistics & numerical data , Benzodiazepines/adverse effects , Hypnotics and Sedatives/adverse effects , Occupational Health , Substance Abuse Detection , Benzodiazepines/urine , Case-Control Studies , Humans , Hypnotics and Sedatives/urine , Substance Abuse Detection/statistics & numerical data
19.
J Anal Toxicol ; 38(6): 327-34, 2014.
Article in English | MEDLINE | ID: mdl-24790062

ABSTRACT

A simple liquid chromatography-tandem mass spectrometry method was validated to allow determination of zopiclone (ZOP), N-desmethylzopiclone (NDZOP), zopiclone N-oxide (ZOPNO) and 2-amino-5-chloropyridine (ACP) in urine at concentrations up to 3,000 ng/mL within 3.5 min. This method was used for quantitative analysis of the analytes in authentic urine samples obtained 10 h after oral administration of zopiclone (Imovane(®)) and in aliquots of the same urine samples after different storage conditions. In addition, pH of each studied urine sample was measured over time. The results showed that formation of ACP occurred at elevated pH and/or temperature by degradation of ZOP, NDZOP and ZOPNO. This method was also applied to samples obtained from two female victims of drug-facilitated assault. One sample had been exposed to long-term storage conditions at different temperatures and at pH >8.2, which resulted in high concentrations of ACP. The other sample, which was exposed to pH <6.5, showed no formation of ACP. ACP is formed both from ZOP and from its metabolites NDZOP and ZOPNO depending on the pH of the urine, time of storage and/or the temperature conditions. For correct interpretation in forensic cases, ZOP, its major metabolites and ACP should be analyzed. When ACP is identified in urine, the concentrations of ZOP, NDZOP and ZOPNO should be interpreted with great caution.


Subject(s)
Azabicyclo Compounds/urine , Hypnotics and Sedatives/urine , Piperazines/urine , Pyridines/urine , Azabicyclo Compounds/metabolism , Chromatography, High Pressure Liquid , Healthy Volunteers , Humans , Hydrogen-Ion Concentration , Hypnotics and Sedatives/metabolism , Limit of Detection , Piperazines/metabolism , Reference Standards , Reproducibility of Results , Tandem Mass Spectrometry
20.
J Anal Toxicol ; 38(6): 322-6, 2014.
Article in English | MEDLINE | ID: mdl-24802157

ABSTRACT

This study examined zolpidem and concurrent opioid, benzodiazepine, other central nervous system (CNS) depressants, and alcohol use. Urine specimens were analyzed using liquid chromatography-mass spectrometry (LC-MS/MS). Specimens were tested for zolpidem (n = 71,919) and separated into a provider-reported medication list documenting (n = 5,257) or not documenting zolpidem use (n = 66,662). Zolpidem-positive specimens were further separated into reported and unreported use cohorts. The total number of zolpidem-positive specimens in the reported and unreported use cohorts was 3,391 and 3,190, respectively. Non-informed prescribers were 4.4% (3,190/71,919) among the general population and 48.5% (3,190/6,581) when only zolpidem users were considered. In the zolpidem user population, the most common concurrent opioids in both cohorts were hydrocodone and oxycodone. Alprazolam and clonazepam were higher in the unreported use cohort (P ≤ 0.05). The unreported use cohort also had a higher detection of zolpidem plus a benzodiazepine (49.7 vs. 46%; P ≤ 0.05), zolpidem plus an opioid and a benzodiazepine (40.8% vs. 37.4%; P ≤ 0.05) and zolpidem plus an opioid, a benzodiazepine, and an other CNS depressant (12.9 vs. 10.9%; P ≤ 0.05). Concurrent use of zolpidem, an opioid, a benzodiazepine and an other CNS depressant is prevalent in a pain patient population.


Subject(s)
Analgesics, Opioid/urine , Hypnotics and Sedatives/urine , Pain/urine , Pyridines/urine , Analgesics, Opioid/therapeutic use , Chromatography, Liquid , Cohort Studies , Drug Interactions , Drug Prescriptions/standards , Drug Prescriptions/statistics & numerical data , Humans , Hypnotics and Sedatives/therapeutic use , Limit of Detection , Pain/drug therapy , Pyridines/therapeutic use , Retrospective Studies , Tandem Mass Spectrometry , Zolpidem
SELECTION OF CITATIONS
SEARCH DETAIL
...